DC Voltage Ranges
- DC Voltage - 600mV/6/60/600/1000V
- Accuracy - ± (0.5%rdg + 3dgt)
AC Voltage Ranges
- AC Voltage - 600mV/6/60/600/750V
- Accuracy - ± (0.8% rdg + 5dgt)
- AC Response - 40Hz ~ 1000Hz
DC Current Ranges
- DC Current - 600/6000µA / 60 / 600 / 1200A
- Accuracy - ± (0.8% rdg + 10dgt) on 600 / 6000µA, ± (2.0% + 30dgt) on 60 / 600 / 1200A
- Overload - 1200A DC Max. for 1min. for A
AC Current Ranges
- AC Current - 600/6000µA / 60 / 600 / 1200A
- Accuracy - ± (2.0% + 30dgt) on all Ranges
- AC Response - 40 Hz ~ 1000Hz
- Overload - 1200A AC Max. for 1min. for A
Resistance Ranges
- Resistance - 600 /6/60/600k /6/60M
- Accuracy - ± (0.8% rdg + 5dgt) on 600 ohm, ± (0.8% rdg + 3dgt) on 6/60/600k-ohm /6Mohm, ± (1.0% rdg + 25dgt) on 60 Mohm
Capacitance Ranges
- Capacitance - 9.999/99.99/999.9nF/9.999/ 99.99/999.9µF/9.999mF
- Accuracy - ± (3.5% rdg + 60dgt) on all ranges except, ± (5.0% rdg + 10dgt) on 999.9µF& 9.999mF
Frequency Ranges
- Frequency - 99.99Hz ~20.00MHz
- Accuracy - ± (0.01% rdg + 3dgt)
Duty Cycle Ranges
- Duty Cycle - 0.1% ~ 99.9%
- Accuracy - ± (0.01% rdg + 3dgt)
Temperature Ranges
- Temperature - -20°C ~ 1000°C / 0°F ~ 1832°F
- Accuracy - ± (1% rdg + 5dgt) on - 20°C ~ 400°C, ± (1.5% rdg + 15dgt) on 400°C ~ 1000°C, ± (0.75% rdg + 5 dgt) on 0°F ~ 750°F, ± (1.5% rdg + 15 dgt) on 750°F ~ 1832°F
µA Measurement for HVAC Flame Sensors Ranges
- µA Measurement for HVAC Flame Sensors - 600.0µA / 6000µA
- Accuracy - ± (1% rdg + 20 dgt)
Accessories : Supplied with Pair of Test Leads, Battery, K Type Thermocouple (upto 260°C), Inst. Manual & Carrying Case