Kondhwa, Pune, Maharashtra
Business Type | Supplier, Retailer, Wholesaler |
Brand Name | Fluke |
Operating temperatures | 18 to 28 Deg. Cel. |
Benefit | Frequency and temperature measurement |
Click to view more |
Preferred Buyer From
Location | Anywhere in India |
Product Details
The Fluke 17B+ digital multimeter does all that and more. Common basic electrical measurements plus temperature, frequency and duty cycle. Easy to use with one hand, even with gloves on, the Fluke 17B+ offers everything you need.
Features :
Accuracy Specifications : Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of : ± (% of Reading + Number of Least Significant Digits).
Battery life : 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Operating humidity
Fluke TPAK ToolPak™ Magnetic Meter Hanger Kit includes:
Technical Specifications
Function | Range | Resolution | Accuracy |
AC volts (40 Hz to 500Hz)1 |
4.000 V 40.00 V 400.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
1.0 % + 3 |
DC volts | 4.000 V 40.00 V 400.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
0.5 % + 3 |
AC millivolts | 400.0 mV | 0.1 mV | 3.0 % + 3 |
DC millivolts | 400.0 mV | 0.1 mV | 1.0 % + 10 |
Diode test2 | 2.000 V | 0.001 V | 0.1 |
Resistance (Ohms) |
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 |
Capacitance3 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
Frequency1 Hz (10 Hz – 100 kHz) |
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
0.1 % + 3 |
Duty Cycle1 | 1 % to 99 % | 0 | 1 % typical 4 |
AC current μA (40 Hz to 400 Hz) |
400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5 % + 3 |
AC current mA (40 Hz to 400 Hz) |
40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5 % + 3 |
AC current A (40 Hz to 400 Hz) |
4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 |
DC current μA | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5 % + 3 |
DC current mA | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5 % + 3 |
DC current A | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 |
Temperature | 50 °C- 400 °C 0 °C- 50 °C -55 °C- 0 °C |
0.1C | 2 % ± 1 °C ± 2 °C 9 % ± 2 °C |
Backlight | - | - | Yes |
AC and DC Voltage
Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
AC volts | 1000 V 1 | >10 MΩ <100 pF | >60 dB at dc, 50 Hz or 60 Hz |
- |
AC millivolts | 400 mV | >1MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | - |
DC volts | 1000 V 1 | >10 MΩ <100 pF | >100 dB at dc, 50 Hz or 60 Hz |
>60 dB at 50 Hz or 60 Hz |
DC millivolts | 400 mV | >1MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | - |
Hi! Simply click below and type your query.
Our experts will reply you very soon.