Kondhwa, Pune, Maharashtra
Business Type | Supplier, Retailer, Wholesaler |
Warranty | 12 Months Warranty |
V AC Range | 600.0 V |
V DC Range | 600.0 V |
Click to view more |
Preferred Buyer From
Location | Anywhere in India |
Product Details
Fluke 101 digital multimeter offers reliable measurements for residential/commercial electricians and heating and air conditioning technicians. This small, lightweight multimeter fits comfortably in your hand but is rugged enough to withstand daily use for years to come. Fluke 101+ Kit Palm Size Digital Multimeter along with Calibration Certificate.
Features :
Fluke 101 Includes:
Fluke 101 Kit Includes:
Fluke 101 / i400E Clamp Bundle Includes:
Electrical Specifications
V AC (40-500Hz) | Range | 600.0 mV 6.000 V 60.00 V 600.0 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V |
|
Accuracy | 3.0%±3 digit 1.0%±3 digit |
|
V DC | Range | 6.000 V 60.00 V 600.0 V |
Resolution | 0.001 V 0.01 V 0.1 V |
|
Accuracy | 0.5%±3 digit | |
Resistance Ohms | Range | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
|
Accuracy | 0.5 %±3 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 0.5 %±2 digit 1.5%±3 digit |
|
Capacitance | Range | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 100.0 μF |
Resolution | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF |
|
Frequency (10 Hz – 100 kHz) |
Range | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
|
Duty Cycle | Range | 0.1 % to 99.9 % |
Resolution | 0 |
Environmental Specifications
Operating Temperature | 0 °C to +40 °C |
Storage Temperature | -30 °C to +60 °C |
Operating Humidity | Non condensing (<10 °C) <=90% RH (at 10 °C to 30 °C) <=75% RH (at 30 °C to 40 °C) (Without Condensation) |
Operating Humidity, 40 Mâ�¦ | 80% RH 10 °C to 30 °C, 70% RH 30 °C to 40 °C |
Operating Altitude | 2,000 meters |
Storage Altitude | 12,000 meters |
IP Rating | IP 40 per IEC 60529 |
Vibration Requirements | MIL-PRF-28800F, Class 2 |
Drop Test Requirements | -10°C and 1 meter to surface, per IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment Shipping container drop per Fluke SOP 39. |
EMI, RFI, EMC | Must meet all applicable requirements in IEC/EN 61326-1 |
Absorption/Corrosion | Per Fluke SOP 39.1 |
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 ºC |