Rishabh Insu 10 Digital Insulation Tester Supplier

Rishabh Insu 10 Digital Insulation Tester
Price : 3,250.00 / Piece
Get Best Price

MOQ : 1 Piece(s)

Business Type Supplier, Retailer, Wholesaler
Brand Name Rishabh
Display Digital
Test voltages from 50V to 1000V
Click to view more

Preferred Buyer From

Location Anywhere in India

Product Details

Storage Memory
For last 50 readings
IEC/EN61326
Electromagnetic Compatibility (EMC)

Features

  • Test Voltages 50V/ 100V/ 250V/ 500V/ 1000V - Test voltages from 50V to 1000V can be selected for Insulation Resistance measurement. It covers all insulation tests up to 1000V.
  • Insulation Resistance Measurement - The instrument is capable of measuring insulation resistance from 10 KOhm - 999 MOhm.
  • Hands-free continuity testing - Continuity testing (0-10 with acoustic signal) can be done without pressing the test button. In addition to the display function, an acoustic signal can be activated which sounds if the adjustable limit value is violated.
  • Voltmeter - Instrument measures voltages > 25V -  600 V AC/DC.
  • Automatic discharge for capacitive circuits after test Measurement - Capacitive devices under test, such as cables and windings that get charged during the test are discharged by the tester.
  • Live circuit detection - Displays presence of voltages > 25V irrespective of function selected.
  • Pre-selectable measurement time for Insulation Resistance Measurement - In normal course, the insulation test terminates and the measured insulation resistance value remains on display for 2 sec after the test key is released. With the Pre-selectable measurement time feature, the insulation test continues and the measured value remains on the display for the pre-determined time. Pre-selectable time: 10 sec - 5 min.
  • Pre-selectable limit checks (Go/ No-go option) for MOhm - An acoustic signal can be generated when the measured value of insulation resistance falls below an adjustable limit value.
  • Lead resistance null facility - The instrument provides a facility to compensate the resistance of the leads for an accurate measurement of low resistance.
  • Storage of MIN/MAX values - In addition to the display of the actual measured value, the minimum or maximum value can constantly be updated or stored.
  • Storage Memory for last 50 readings - The instrument provides a facility to store and recall 10 values in each of the 5 ranges of insulation resistance measurement.
  • Blown fuse indication - The display FUSE points to a blown fuse.
  • Stop Watch - This function allows you to measure elapsed time up to 1 hour.
  • Auto-power off function - The instrument turns off automatically, if any of the keys or the instrument turns off automatically, if any of the keys or the selector switch have not been activated for about 10 minutes in insulation range and 5 minutes in other ranges or can be switched to continuous operation.
  • Protective holster for rough duty - A holster of soft rubber with tilt stand protects the meter against damage in the case of shock and drop.
  • Low Resistances Measurement (0.01Ohm... 99.9 Ohm) - Low resistances can be measured up to 99.9Ohm. There are two measuring ranges for Low W: 9.99Ohm and 99.9Ohm.


Applications : RISH Insu10 Analog-Digital Insulation and Continuity Tester is suitable for following

  • Measurement of the insulation resistance on electrically dead equipment and systems with test voltages up to 1000V.
  • For testing motors, transformers, generators, switchgears.
  • For testing of house hold appliances.
  • Measurement of the insulation resistance of cables.
  • Very useful for on-site maintenance and service departments


Power Supply

  • Battery - 6 x 1.5 V cells IEC LR6 (Nickel cadmium rechargeable cells may be used)
  • Service Life - Typically 2500 x 5 sec. operations
  • Battery Test - Automatic display of the Symbol ”when battery voltage < 5.4V.


Note : Battery cells should not be left in the instrument which may remain unused for extended period of time.

Environmental conditions

  • Temperature Coefficient - <0.1% per °C
  • Operating Temp.-  -20°C...+40°C (full range), -20°C...+60°C (upto 100M )
  • Storage Temp. - -25°C...+65°C
  • Relative Humidity - 90% RH at 40°C max


Display : LCD display field (65 mm x 30mm) with analog indication and digital display and with display of unit of measured quantity and functions

Digital

  • Display/Char. Height - 7 segment digits/ 12mm
  • Number of Digits - 3 digit for M ohm and 4 digit for Stop watch
  • Overflow Display - OL


Reference Conditions

  • Ambient Temp -  +23 °C + 2 K
  • Relative Humidity - 45% ... 55%
  • Battery Voltage - 8V + 0.1V
  • Voltage Measurement - AC (Sine), 50/60 Hz


Auto turn OFF : Meter turns off automatically, if any of the keys or the selector switch have not been activated for about 10minutes in insulation range and 5 minutes in other ranges.
Fuse 500 mA(F) / 440V H.B.C.10kAmin (32mm x 6mm)

Electrical Safety

  • Protection class - II per IEC 61010-1/EN61010-1/ VDE0411-1
  • Overvoltage - Category II - 600V, Category III - 300V
  • Contamination degree - 2 in each
  • Test Voltage - 3.7KV-per IEC 61010-1 /EN61010-1


Mechanical Design

  • Protection
    • Instrument - IP 50
    • For terminal socket - IP 20 according to DIN VDE 0470 part 1 / EN60529
  • Dimensions W x H x D - 84 mm x 195 mm x 35 mm
  • Weight - 500 g including battery

Yes! I am interested


Technical Data

Meas. Function Range Resolution Accuracy +(...% of rdg + ...Digit Overload value & duration
Insulation 0.01 M to 0.99 MΩ 10 KΩ (0.01 MΩ ) +- 3% + 2D 1200 Vrms 10 sec
Resistance M- ohm >1.0 M to 9.9 MΩ 100 K Ω (0.1 MΩ) +- 5% + 2D
U =50V, 100 V >10 M to 99 MΩ 1MΩ +- 30 %
Insulation 0.01 M to 9.99 M Ω 10 kΩ (0.01 mΩ) +- 3% + 2D 1200 Vrms 10 sec
Resistance M- ohm >10.0 M to 99.9 M Ω 100 KΩ (0.1 MΩ) +- 5% + 2D
U =250V, 500 V, 100 V >100 M to 999MΩ 1 MΩ +- 30 %
Low Ohms 0 to 9.99 Ω 0.01Ω at 210 mA +- 3% + 2D 1200 Vrms 10 sec
>10 to 99.9 Ω 0.1Ω at 21 mA +- 5% + 2D
Continuity 0 to 9.99Ω 0.01Ω at 210 mA +- 30 %
>10 to 99.9 Ω 0.1Ω at 21 mA +- 3% + 2D 1200 Vrms 10 sec
V AC/DC 25V to 450V 1 V +- 2% + 3D
450V to 600V 1 V +- 3 %